Skip to content

Online DGA

Next Generation Multi On-Line Dissolved Gas Analyser(DGA)

Dissolved Gas Analyser(DGA) and moisture measurement of insulating fluids are recognized as the most important tests for condition assessment of transformers. In previous years, multi-gas DGA was traditionally confined to a laboratory environment, with infrequent off-line manual sampling forming part of time-based maintenance strategies. However, as the global average age of transformers continued to rise, the possibility of rapid ageing, unplanned outages and even catastrophic failure between off-line tests also increased, leading many asset owners to adopt on-line DGA monitoring strategies to increase network reliability.

In the early 2000’s, GE’s Kelman™ range of analyser brought consumable-free on-line multi-gas DGA to the market and GE is now proud to introduce the Kelman DGA 900, our next generation multi-gas on-line DGA and moisture analyser. At its heart lies an evolved implementation of GE’s proven Photo- Acoustic Spectroscopy (PAS) measurement technology, providing laboratory challenging levels of precision and repeatability with no consumables and no need for frequent re-calibration. Benefiting from over 40 years of global of Dissolved Gas Analyser vendor experience, the Kelman DGA 900 encapsulates learnings and improvements derived from its predecessors to bring improved performance, innovative new features, enhanced user experience and increased robustness.

Key Benefits of Dissolved Gas Analyser

• Provides remote alert and multi-gas diagnostic of deteriorating transformer condition.
• Expedites operational decisions without needing to go to site for manual oil sampling.
• Issues can be detected in their infancy, avoiding unexpected failures and facilitating planned outages.
• Anchors condition based maintenance and asset replacement strategies on hard data.
• No need for consumables or frequent recalibration to operate at optimum performance.
• New “Rapid Mode” provides near real time insight on fast developing faults.
• Enhanced computing power, highly scalable I/Os and integrated HMI combine to provide a powerful highly flexible transformer monitoring solution.
• Compatible with mineral insulating oils and newer ester based fluids (natural and synthetic).

Applications of Dissolved Gas Analyser

  • The Kelman DGA 900 is an invaluable foundational tool for implementing Asset Performance Management (APM) across electrical generation, transmission and industry, enabling a condition based asset replacement strategy and delivering improvements in system reliability and availability.
  • A DS-Agile™ and PREDIX™ Grid APM ready device, the DGA 900’s wide range of communication methods and protocols enables connection to those platforms and integration with GE’s Perception™ transformer fleet management software as well as other software, historian and SCADA systems.

Range

 LDLUDLAccuracy*RepeatabilityAvailable in Rapid Mode
Hydrogen (H₂)5 –5,000 ppm± LDL or ±5%< 3%
Carb. Monox. (CO)1 –50,000 ppm± LDL or ±3%< 2%
Methane (CH₄)2 –50,000 ppm± LDL or ±3%< 2% 
Acetylene (C₂H₂)0.5 –50,000 ppm± LDL or ±3%< 2%
Ethylene (C₂H₄)1 –50,000 ppm± LDL or ±3%< 2% 
Carb. Diox. (CO₂)20 –50,000 ppm± LDL or ±3%< 3%
Ethane (C₂H₆)1 –50,000 ppm± LDL or ±3%< 2% 
Oxygen (O₂)100 –50,000 ppm± LDL or ±5%< 2%
Nitrogen (N₂) **10,000 –100,000 ppm± LDL or ±15%  
Moisture (H₂O)0 –100% RS (in ppm)± 3% RH< 3%

*whichever is greater. Accuracy quoted is the accuracy of the detectors during calibration. Gas-in-oil measurement may be affected by oil type and condition. Repeatability as measured from final production test data.
** N₂ value is calculated and available on free-breathing transformers only.

Features of of Dissolved Gas Analyser

  • Display
    4x sunlight visible LED arrays
    Backlit 7” inch color resistive touch LCD screen (800 x 480)
    Integrated embedded secure webserver (https)
  • Analogue Inputs
    Up to 15x optional analogue inputs for load CTs, PT100 inputs or 4–20mA sensors
  • Digital Output
    USB port (type B connector) for local connection to laptop computer for configuring the system
    Wi-Fi (802.11b/g/n)
    Serial output (RS-485)
    1Gb Ethernet (RJ45) standard with fiber-optic options
    GSM/GPRS or CDMA/LTE modem options
  • Digital Protocols
    Modbus® as standard
    DNP3 or IEC 61850 (Ed 1 or 2) options
  • Alarms
    Alarm setting screens/scenarios, based on gas level, gas rate of change and moisture level, assignable to relays 6x standard and up to 18x dry contact relays (type C, SPDT), NO/NC, 10A at 250Vac resistive load, 10A at 30Vdc resistive load Separate Service Alarm with own relay.
  • ENVIRONMENT Conditions
    Operating ambient temperature :- -40°C to +55°C (-40°F to +131°F)
    Operating ambient humidity :- 0-95% RH, non-condensing
    Oil temperature at valve*** :- -20°C to +120°C (-4°F to +248°F)
    Oil pressure at valve :- 0-700KPa (0-100psi)

***Based on testing carried out using VOLTESSO™ 35 mineral oil, over a ¼” pipe run of 10 metres or less from oil supply or
return valve to monitor connection point and on transformer oil supply valve volumes of 200ml or less. For oil temperatures
colder than -20ºC, GE recommends the use of heat trace cabling on piping.

Enclosure
IP56 certified
Powder coated aluminium (RAL9002)
Unpainted 316 Stainless Steel option

Power Requirements
AC :- Nominal 100-240 Vac, Range 85-264 Vac, 4A
DC :-  Nominal 100-250 Vdc, Range 90-300 Vdc

Mechanical

 Analysis UnitHub Unit
Dimensions600 x 484 x 330 mm600 x 380 x 330 mm
 23.6 x 19.1 x 13.0 in23.6 x 15.0 x 13.0 in
Weight33.4Kg18.5Kg
 73.6 lb40.8 lb

OPTIONS
Mounting stand
Sun canopy
Umbilical cable between units
Analogue output of gas values

Related products

Gas Chromatography Equipment Price

Head Space TOGA Analyzer

The Touch Screen GC System Model Dhruva S2TS.

Portable Gas Chromatography Equipment

P–Micro DGA Analyzer

This equipment can be used to detect the incipient fault in the transformer.

Portable Dissolved Gas Analyzer

Portable DGA

Dissolved Gas Analysis (DGA) and moisture measurement of insulating fluids

Partial Discharge Monitoring System For Transformers

Online PD

Bushing Monitoring and Partial Discharge Detection for Transformers.

Distribution Transformer Monitoring

Online Transformer Monitoring system

Faced with increasing pressure to continuously improve network availability.

Quick Inquiry