Skip to content

Transformer Health: Dissolved Gas Analysis of Transformer Oil

Dissolved Gas Analysis Of Transformer Oil

Dissolved Gas Analysis (DGA) of transformer oil is an essential tool for safeguarding the health and reliability of transformers. By monitoring the gases present in the oil, such as hydrogen, methane, ethane, and acetylene, this analysis offers a predictive insight into the transformer’s condition. DGA helps detect incipient faults, overheating, and other potential issues before they escalate, allowing for timely maintenance and preventing catastrophic failures. This comprehensive guide will take you through the significance of DGA, how it works, and its role in ensuring the longevity of transformer assets.

Introducing Dissolved Gas Analysis (DGA)

Dissolved Gas Analysis (DGA) is a diagnostic tool used to assess the health and condition of transformers. It involves the detection and analysis of specific gases dissolved in the insulating oil of the transformer. When a transformer experiences a fault or begins to deteriorate, various gases are generated as a byproduct of this process. These gases serve as crucial indicators of the transformer’s condition, and by analyzing them, experts can predict potential issues before they escalate into more severe problems.

The most significant gases generated during the decomposition of oil and paper insulation in transformers include:

  1. Hydrogen (H2): The presence of hydrogen is often a sign of overheating or partial discharge within the transformer. Hydrogen levels can vary depending on the severity of the fault.
  2. Methane (CH4): Methane can be an indicator of arcing or overheating in the transformer. Like hydrogen, its presence can signal potential issues.
  3. Ethane (C2H6): Elevated levels of ethane can indicate overheating or electrical breakdown within the transformer.
  4. Ethylene (C2H4): Ethylene is often associated with overheating or high-temperature hot spots within the transformer.
  5. Acetylene (C2H2): Acetylene is a significant gas to monitor, as its presence can indicate arcing or severe electrical faults.
  6. Carbon Monoxide (CO): The presence of carbon monoxide can be linked to issues such as overheating and insulation degradation.
  7. Carbon Dioxide (CO2): Elevated carbon dioxide levels are often associated with thermal faults.
  8. Oxygen (O2): A decrease in oxygen levels can be indicative of various issues, including oil degradation and reduced dielectric strength.
  9. Nitrogen (N2): Nitrogen levels can change as a result of partial discharge or overheating within the transformer.

By analyzing the quantities of these gases in the transformer oil, experts can determine the type and severity of the fault condition. It’s important to note that different fault conditions result in varying gas combinations, concentrations, and patterns, making DGA an invaluable diagnostic tool.

Detail description of Dissolved Gas Analyser

  • Color Touch Screen control with optional control over TCP-IP using FTP protocol.
  • Meets  ASTM D 3612  Section A or C or IEC 60567, 2005 Section 7.3 or 7.5 as required by the user.
  • 10 or 40  Vial Head Space Auto Sampler (Choice of Manual Head Space Sampling as per Section C / 7.5) .
  • Auto tuning PID temperature control for up to 8 channels with 2 programmable zones & 6 isothermal zones.
  • EPC for up to 8 channels with 2 programmable zones & 6 single set point control with 0.25 % FSD accuracy.
  • Up to 12 auxiliary device control with 4 step programming for control of GSV, Solenoids, Pumps, trigger, signals etc.
  • Input status for Pressure, Remote start, Remote Stop, Door open along with 4 additional spare inputs.
  • Programmable FID (Gain, Off Set, and Sensitivity – low, high) with time based sensitivity settings.
  • Programmable TCD (Sensitivity – Low, Medium, High) with superb current stability & repeatability.
  • Extensive Auto diagnostics & user friendly system control with User settable password protection. Multi mode screens with 6 pages of current status giving complete GC status with option for continuous looping of the system.

In the realm of power generation and distribution, transformers serve as the unsung heroes that enable the seamless flow of electricity from the power plants to our homes and industries. These vital components silently step down or step up the voltage levels to ensure that electricity reaches us in the right form. However, like any other piece of equipment, transformers have a finite lifespan, and their health gradually deteriorates over time due to a combination of factors.

One of the key challenges faced by those responsible for managing transformers is predicting when these critical components might fail. Transformer failures can be catastrophic, leading to power outages, costly repairs, and, in some cases, environmental hazards. To address this issue, engineers and experts have turned to advanced diagnostic techniques, one of the most critical being Dissolved Gas Analysis (DGA) of transformer oil. This essential tool provides invaluable insights into the transformer’s condition, helping prevent unplanned outages and safeguarding the reliability of power distribution systems.

In this comprehensive guide, we will delve into the world of Dissolved Gas Analysis of transformer oil. We will explore the significance of DGA, its role in predicting transformer health, the gas chromatography method used for detection, and the specific gases that signal potential issues. Additionally, we will take a closer look at a state-of-the-art system, the Touch Screen GC System Model Dhruva S2TS, approved by NTPC and ERDA, which ensures precise DGA and preventive measures for transformers.

Understanding the Transformer’s Vital Role

Before we embark on our journey to explore Dissolved Gas Analysis, it’s essential to understand the crucial role that transformers play in the world of power distribution. These unassuming devices step up or step down voltage levels, ensuring that electricity flows safely and efficiently from power plants to homes and industries. In essence, they bridge the gap between power generation and power consumption, making it possible for us to enjoy the benefits of electricity.

Transformers come in various shapes and sizes, serving different purposes across power distribution systems. Whether they are small distribution transformers found on power poles in residential neighborhoods or massive generators at power stations, all transformers share a common goal: transforming electricity from one voltage level to another. However, their operational environments and conditions may vary significantly, leading to differences in their health and reliability.

The Aging Transformers Dilemma

As transformers age, their reliability gradually declines. Several factors contribute to the aging process, including mechanical stress, electrical stress, temperature variations, and environmental conditions. Transformers work tirelessly, year after year, experiencing constant thermal cycling, load fluctuations, and exposure to environmental elements.

To mitigate the risk of catastrophic transformer failures, it’s essential to monitor their condition and anticipate potential issues. While regular maintenance is crucial, it often involves offline manual sampling and laboratory analysis, which can result in extended turnaround times. Unfortunately, transformers don’t always wait for these tests, and critical problems can arise between scheduled maintenance checks.

To bridge this gap, on-line Dissolved Gas Analysis (DGA) has emerged as a powerful tool for monitoring transformer health. Instead of relying solely on time-based maintenance strategies, DGA allows for continuous monitoring, providing early warnings of potential issues and enabling timely maintenance or preventive measures.

The Process of Dissolved Gas Analysis

Dissolved Gas Analysis typically follows a systematic process that involves the separation, identification, and quantitative determination of gases present in the transformer oil. The Touch Screen GC System Model Dhruva S2TS, which is NTPC and ERDA approved, is a state-of-the-art solution designed to execute this process with precision and efficiency.

The equipment utilizes Gas Chromatography, a technique that separates gas mixtures into individual components for analysis. Here’s an overview of the key steps involved in DGA using the Dhruva S2TS system:

  1. Sample Collection: A sample of the transformer oil is collected and prepared for analysis.
  2. Injection: The prepared sample is injected into the gas chromatograph, which is a crucial component for gas separation.
  3. Gas Separation: Within the gas chromatograph, the various gases within the sample are separated based on their individual chemical properties.
  4. Detection: After separation, each gas component is detected, quantified, and identified based on its unique characteristics.
  5. Data Analysis: The results are analyzed and interpreted to understand the transformer’s condition. Different fault types generate distinct gas patterns, and the data is used to predict potential issues and take preventive measures.

The Dhruva S2TS system excels in its ability to analyze fault gases in a single injection, with the gases analyzed depending on user preferences and requirements. This customization ensures that the system is tailored to the specific needs of the transformer being monitored.

Who are We?

Manufacturer
supplier
trader
importer
exporter
company
solution

Where do we have clients and supply our Dissolved Gas Analysis Of Transformer Oil ?

IndiaUnited Arab EmiratesUganda
NepalIsraelTanzania
VietnamEgyptAngola
PhilippinesYemenKambia
IndonesiaTurkeyMalawi
MalaysiaSudanBotswana
South KoreaAlgeriaSouth Africa
OmanMonacoZimbabwe
IranNigeriaCambodia
Saudi ArabiaEthiopiaAustralia
NamibiaGreeceUSA

Advantages of Dissolved Gas Analysis Of Transformer Oil

Dissolved Gas Analysis (DGA) of transformer oil is a critical diagnostic tool used to assess the health and condition of transformers. It offers several key advantages that make it an indispensable component of modern maintenance strategies in the power industry. Let’s delve into the advantages of DGA in safeguarding transformers and ensuring the reliability of power distribution networks:

1. Early Fault Detection:

  • One of the primary advantages of DGA is its ability to detect incipient faults in transformers at an early stage.
  • DGA can identify developing issues even before they become critical, allowing for timely intervention and preventive measures.

2. Predictive Maintenance:

  • DGA empowers asset owners and engineers to transition from time-based maintenance to predictive maintenance strategies.
  • By continuously monitoring the health of the transformer, maintenance can be planned based on actual condition rather than scheduled intervals, reducing operational disruptions and costs.

3. Minimizing Unplanned Outages:

  • With early fault detection, DGA significantly reduces the risk of unplanned outages.
  • By addressing issues proactively, asset owners can avoid costly repairs and maintain a more reliable power distribution network.

4. Detailed Diagnostic Data:

  • DGA provides in-depth insights into the condition of the transformer.
  • Engineers and experts can access valuable data that helps them make informed decisions regarding the operation and maintenance of the transformer.

5. Customization:

  • DGA systems, such as the Touch Screen GC System Model Dhruva S2TS, offer the flexibility to customize the analysis based on user preferences and specific transformer requirements.
  • This customization ensures that the system is tailored to the needs of the transformer being monitored, providing precise and relevant information.

6. Enhanced Safety:

  • By identifying and addressing faults early, DGA contributes to the safety of power distribution systems.
  • It helps prevent catastrophic failures that could result in safety hazards, environmental damage, and financial losses.

7. Reduced Operational Costs:

  • DGA allows for cost-effective maintenance strategies that focus resources where they are most needed.
  • By minimizing unnecessary maintenance and repairs, operational costs are reduced, resulting in more efficient asset management.

8. Extension of Transformer Lifespan:

  • Through early fault detection and timely intervention, DGA contributes to extending the lifespan of transformers.
  • This maximizes the return on investment for these critical assets.